主要特性和功能
非常適合對(duì)同軸器件或晶圓器件進(jìn)行表征、建模和參數(shù)提取
對(duì)器件施加精確的調(diào)平功率,進(jìn)行功率掃描
使用唯一集成三軸偏置 T 型接頭的寬帶解決方案,精確控制器件的偏置狀態(tài)
可購(gòu)買(mǎi)單一產(chǎn)品解決方案或由多個(gè)單獨(dú)元器件組成的配置
分段毫米波解決方案可在高達(dá) 1.1 THz 的頻率上測(cè)量 S 參數(shù)
技術(shù)指標(biāo)
最大頻率?? ?110 GHz
動(dòng)態(tài)范圍?? ?128 dB
輸出功率?? ?13 dBm
內(nèi)置端口數(shù)量?? ?2 或 4 端口
本底噪聲?? ?-117 dBm
網(wǎng)絡(luò)分析儀系列?? ?PNA 高性能
應(yīng)用?? ?寬帶測(cè)量
元器件?? ?晶圓上
臺(tái)式?? ? 是
Hardware Options
N5251A-200?? ?2 port, PNA opt 201, N5261A test set, 2 mods w/ bias tees, atten on left mod only
N5251A-217?? ?2 port, PNA opt 201, N5261A test set, 2 mods w/ bias tees, attens on both mods
N5251A-218?? ?2 port, PNA opt 219, N5261A test set, 2 mods w/ bias tees, atten on left mod only
N5251A-219?? ?2 port, PNA opt 219, N5261A test set, 2 mods w/ bias tees, attens on both mods
N5251A-400?? ?4 port, PNA opt 401, N5262A test set, 4 mods w/ bias tees, attens on left mods only
N5251A-417?? ?4 port, PNA opt 401, N5262A test set, 4 mods w/ bias tees, attens on all mods
N5251A-418?? ?4 port, PNA opt 419, N5262A test set, 4 mods w/ bias tees, attens on left mods only
N5251A-419?? ?4 port, PNA opt 419, N5262A test set, 4 mods w/ bias tees, attens on all mods
Hardware options
N5227A-200?? ?2 ports, single source, base hardware configuration
N5227A-201?? ?2 ports, single source, with configurable test set
N5227A-210?? ?2 ports, single source, with metrology configuration
N5227A-219?? ?2 ports, single source, configurable test set, extended power range, bias-tees
N5227A-400?? ?4 ports, dual source, base hardware configuration
N5227A-401?? ?4 ports, dual source, with configurable test set
N5227A-410?? ?4 ports, dual source, with metrology configuration
N5227A-419?? ?4 ports, dual source, configurable test set, extended power range, bias-tees
Additional capability
N5227A-008?? ?Pulsed RF Measurements
N5227A-010?? ?Time Domain
N5227A-020?? ?Add IF inputs
N5227A-021?? ?Add pulse modulator to internal first source
N5227A-022?? ?Add pulse modulator to internal second source
N5227A-025?? ?Add four internal pulse generators
N5227A-028?? ?Noise figure measurements using standard receivers
N5227A-080?? ?Frequency offset measurements
N5227A-082?? ?Scalar calibrated converter measurements
N5227A-083?? ?Vector and scalar calibrated converter measurements
N5227A-084?? ?Embedded LO measurements
N5227A-086?? ?Gain compression application
N5227A-087?? ?Intermodulation distortion measurements
N5227A-118?? ?Fast CW Mode
N5227A-460?? ?Integrated true-mode stimulus application
N5227A-551?? ?N-port calibrated measurements
N5227A-302?? ?Application for use with temperature-characterized CalPods
N5227A-301?? ?Application for use with standard CalPods
N5227A-088?? ?Source Phase Control
N5227A-089?? ?Differential and I/Q devices application
N5227A-007?? ?Automatic Fixture Removal
N5227A-015?? ?Dynamic Uncertainty for S-Parameter Measurements
N5227A-090?? ?Spectrum Analyzer
N5227A-093?? ?Extended Spectrum Analyzer to 110 GHz
N5227A-094?? ?Extended Spectrum Analyzer above 110 GHz
Calibration Software for Self-Maintainers
N5227A-897?? ?Built-in performance test software for inclusive calibration, perpetual license
N5227A-898?? ?Built-in performance test software for standards compliant calibration, perpetual license
Calibration documentation
N5227A-1A7?? ?Calibration + Uncertainties + Guardbanding (Not Accredited)
N5227A-A6J?? ?ANSI Z540-1-1994 Calibration
N5227A-UK6?? ?Commercial calibration certificate with test data
Documents
N5251A-0B0?? ?Download the product manual from the Keysight website
N5251A-ABA?? ?Printed manual English